DC Fuses and Fuse Blocks
( number of products: 118 )
Egis 8032B ATO/ATC Fuse Block, RT Series, 18 Circuits, with LEDs

Egis 8033B Fuse Block, Split Bus, 13 Circuits + Ground, 200 A, 12/24 V

Egis 8031B ATO/ATC Fuse Block, RT Series, 18 Circuits + Ground, with LEDs

Egis 8023B ATO Fuse Block, RT Series, 4 Circuits, Battery Terminal Mount

Egis 8029B ATO/ATC Fuse Block, RT Series, 12 Circuits, with LEDs

Egis 4730-50B Short Stop Circuit Breaker, 50 A, Surface Mount

Egis 4730-25B Short Stop Circuit Breaker, 25 A, Surface Mount

Egis 4730-30B Short Stop Circuit Breaker, 30 A, Surface Mount

Egis 4730-40B Short Stop Circuit Breaker, 40 A, Surface Mount

Egis 4730-20B Short Stop Circuit Breaker, 20 A, Surface Mount

Egis 4712-50B Circuit Breaker, 50 A, with Reset Button, Panel Mount

Egis 4712-60B Circuit Breaker, 60 A, with Reset Button, Panel Mount

Egis 4730-10B Short Stop Circuit Breaker, 10 A, Surface Mount

Egis 4730-15B Short Stop Circuit Breaker, 15 A, Surface Mount

Egis 4712-20B Circuit Breaker, 20 A, with Reset Button, Panel Mount

Egis 4712-30B Circuit Breaker, 30 A, with Reset Button, Panel Mount

Egis 4712-40B Circuit Breaker, 40 A, with Reset Button, Panel Mount

Egis 4707-135B Circuit Breaker, 135 A, 87 Series, Panel Mount

Egis 4707-150B Circuit Breaker, 150 A, 87 Series, Panel Mount

Egis 4707-200B Circuit Breaker, 200 A, 87 Series, Panel Mount

Egis 4707-250B Circuit Breaker, 250 A, 87 Series, Panel Mount

Egis 4712-15B Circuit Breaker, 15 A, with Reset Button, Panel Mount

Egis 4707-040B Circuit Breaker, 40 A, 87 Series, Panel Mount

Egis 4707-050B Circuit Breaker, 50 A, 87 Series, Panel Mount

Egis 4707-060B Circuit Breaker, 60 A, 87 Series, Panel Mount

Egis 4707-070B Circuit Breaker, 70 A, 87 Series, Panel Mount

Egis 4707-120B Circuit Breaker, 120 A, 87 Series, Panel Mount

Egis 4704-090B Circuit Breaker, 90 A, 87 Series, Surface Mount

Egis 4605-1111B Harness for 8+2 Fuse Block, Circuits 1–4, 1.5 m

Egis 4605-4444B Harness for 8+2 Fuse Block, Circuits 1–4, 6 m
The fuse is the cheapest component of an electrical system, and at the same time the one that decides whether a short circuit ends with a blown fuse or a fire on board. In this category you will find fuses, distribution blocks and holders for 12 V and 24 V systems.
The rule people forget
A fuse protects the cable, not the consumer. It is sized to the cross-section and length of the cable, not to the power of the device at the end. A fuse that is too large on a thin cable means the cable can catch fire before the fuse blows.
Circuit breakers and MRBF fuses
Circuit breakers (resettable fuses) are reset with a lever or button after tripping. Our range includes panel-mount and surface-mount models from 5 A to 250 A, including the 85 and 87 series, ATM Mini and short stop. MRBF fuses from 30 A to 300 A are mounted directly on the battery terminal, in MRBF blocks.
Fuse block or individual holders
With more than two or three circuits, a distribution block is more convenient, clearer and less prone to faults than a set of holders scattered around the installation. Models with blown-fuse indication save time when troubleshooting.
Marine-grade construction
Moisture and salt corrode contacts, and a corroded contact heats up and increases circuit resistance. Blocks in sealed housings and corrosion-resistant terminals are not a luxury on a boat but a practical necessity.
Label your circuits
A durable label at each fuse takes five minutes and pays off at the first fault at night on the water.
We will help you match fuses to the cable cross-sections in your installation.
Frequently asked questions
Fuse or circuit breaker?
A circuit breaker suits circuits that occasionally trip, because after tripping you simply reset it. A fuse is simpler and cheaper, but has to be replaced once it blows.
What is a fuse block with a negative bus for?
It brings together the circuit protection and the negative returns in one place. It simplifies wiring and makes troubleshooting easier.
Where should an MRBF fuse be fitted?
Directly on the positive battery terminal, in an MRBF block. This keeps the unprotected length of cable as short as possible.