Isolation transformers & galvanic isolators
( number of products: 10 )
Victron Energy Galvanic Isolator VDI-64A

Victron Energy Galvanic Isolator VDI-32A

Victron Energy Galvanic Isolator VDI-16A

Victron Energy Autotransformer 120/240V 100A

Victron Energy Autotransformer 120/240V 32A

Victron Energy Isolation Transformer 3600W AUTO 115/230V

Victron Energy Isolation Transformer 7000W 230V

Victron Energy Isolation Transformer 3600W 115/230V

Victron Energy Isolation Transformer 2000W 115/230V
Devices that protect the installation and underwater fittings against stray currents from the harbour supply. Our range includes Victron VDI 16, 32 and 64 A galvanic isolators, isolation transformers from 2000 to 7000 W, 120/240 V autotransformers and the Ratio AC16 isolator.
What the problem is
Once you plug into the marina supply, the protective earth conductor connects your boat's ground to that of every other boat on the pontoon. This creates a galvanic cell in which metals with different potentials start to dissolve. In practice this means anodes eaten away in one season instead of three, pitting on the shaft and propeller and, in extreme cases, gearbox damage.
The problem gets worse when the boat is permanently moored in the same berth and is next to boats with faulty installations.
Galvanic isolator or transformer
- A galvanic isolator blocks DC current in the protective earth conductor while keeping its protective function in the event of a short circuit. It is cheaper, lighter and easier to install, and sufficient for most leisure boats
- An isolation transformer completely separates the shore and onboard circuits, with no electrical connection between them. It protects more effectively, also removes the voltage differences between 115 V and 230 V supplies and stabilises the voltage on a weak shore connection
A transformer weighs several tens of kilograms and needs space and careful weight distribution, so on smaller boats a galvanic isolator is usually the more sensible choice.
Autotransformers
They are used to change voltage and split phases in American 120/240 V installations. You need one if the boat has 120 V equipment and you moor in ports with a 230 V supply, or the other way round.
The device is installed in the supply line between the hull socket and the onboard distribution panel.
Frequently asked questions
How do I know I have a galvanic corrosion problem?
The first sign is anodes wearing noticeably faster than on neighbouring boats on the same pontoon. The second is a whitish deposit and pitting on aluminium alloy parts below the waterline.
Does a galvanic isolator reduce the safety of the installation?
No. The design lets fault current through, so the residual current protection works normally. Only the low DC voltage responsible for corrosion is blocked.
What current rating should the isolator have?
It should match the protection rating of the shore connection. For a 16 A socket choose the VDI-16A, for 32 A the VDI-32A.